Every term a quote, a spec sheet, or a technician might use — defined in plain language, linked to the guide that explains it.

A

AFUE (Annual Fuel Utilization Efficiency)
The percentage of fuel a furnace or boiler converts into usable heat over a season. An 80% AFUE furnace loses about 20% of fuel energy up the flue; modern condensing models reach 95–98%.
How a gas furnace works
AHJ (Authority Having Jurisdiction)
The local authority — typically your city's building department — that enforces codes and issues permits. Each Des Moines-metro city administers its own.
HVAC permits in the metro
Air handler
The indoor unit that moves air through your ducts — blower, coil, and controls in one cabinet. In furnace-based systems, the furnace itself acts as the air handler.
Anode rod
A sacrificial magnesium or aluminum rod inside a tank water heater that corrodes in place of the steel tank. Consumed in 3–5 years; replacing it is the cheapest way to extend tank life.
How long do water heaters last?
Auxiliary (backup) heat
The secondary heat source — electric resistance strips or a gas furnace — that assists a heat pump during deep cold. Its configuration determines winter operating cost.
Do heat pumps work in Iowa winters?

B

Balance point
The outdoor temperature below which a heat pump can no longer carry the full heating load (thermal balance point) — or below which gas becomes cheaper to run (economic balance point). Dual-fuel systems switch fuels here.
Heat pump vs. furnace for Iowa
BTU (British Thermal Unit)
The basic unit of heating and cooling capacity. One BTU raises one pound of water 1°F; residential equipment is rated in thousands of BTU per hour (e.g., a 60,000 BTU furnace).

C

C-wire (common wire)
The thermostat wire that provides continuous 24V power. Many smart thermostats require one; older Des Moines homes often lack it, which is a solvable install detail.
Smart thermostat installation
Cold-climate heat pump
A heat pump engineered (inverter compressor, enhanced refrigerant circuit) to maintain meaningful heating capacity at sub-zero outdoor temperatures — the class that made heat pumps viable in Iowa.
Do heat pumps work in Iowa winters?
Commissioning
The measured verification that a new system performs to spec — refrigerant charge by superheat/subcooling, airflow, temperature split, staging. The step that separates installed from installed correctly.
AC installation: what to expect
Compressor
The pump at the heart of every AC and heat pump that pressurizes refrigerant to move heat. The most expensive component — its failure usually drives the repair-vs-replace decision.
AC repair vs. replace
Condensate
Water produced when an AC coil dehumidifies air, or by a condensing furnace extracting extra heat from exhaust. It must drain somewhere — blocked condensate lines are a common service call.
Condenser (outdoor unit)
The outdoor half of an AC or heat pump: compressor, condenser coil, and fan. It rejects the heat collected indoors to the outside air.
Condensing furnace
A 90%+ AFUE furnace with a second heat exchanger that captures heat from exhaust gases until water vapor condenses. Vents in PVC through a sidewall and produces condensate.
Furnace replacement cost drivers

D

Dual-fuel system
A heat pump paired with a gas furnace: the heat pump handles most of the season efficiently, the furnace takes over below the balance point. The hedged configuration for Iowa winters.
Heat pump vs. furnace for Iowa
Ductless mini-split
A heating/cooling system with an outdoor compressor and slim indoor wall units connected by refrigerant lines — no ducts. Each indoor head is its own independently controlled zone.
What is a ductless mini-split?

E

Economizer
A commercial rooftop-unit feature that cools with outdoor air when conditions allow instead of running the compressor — 'free cooling' when it's mild outside.
Light commercial HVAC
Evaporator coil
The indoor coil (usually atop the furnace) where refrigerant absorbs heat and moisture condenses out of household air. Coil leaks on aging systems are a classic replacement trigger.

F

Flame sensor
A safety probe that confirms furnace burners actually lit. A dirty flame sensor is the most common cause of a furnace that starts, runs seconds, and shuts down.
How a gas furnace works

H

Heat exchanger
The sealed metal passages inside a furnace that transfer combustion heat to household air while keeping exhaust gases separate. A cracked heat exchanger is a safety issue and usually ends the repair conversation.
Furnace repair vs. replace
Heat pump
An air conditioner that runs both directions: it moves heat out of your home in summer and into it in winter. Delivers 2–3 units of heat per unit of electricity in most conditions.
Do heat pumps work in Iowa winters?
Hydronic heating
Heating that circulates hot water (or steam) through radiators, baseboards, or floor tubing instead of blowing air — the system older Des Moines neighborhoods were built around.
How boiler heat works

I

Inverter (variable-speed) compressor
A compressor that modulates output continuously instead of cycling on/off. The technology behind cold-climate heat pumps, quieter operation, and better dehumidification.

L

Load calculation (Manual J)
The room-by-room engineering calculation of how much heating and cooling a home actually needs, based on insulation, windows, orientation, and air leakage. The correct basis for equipment sizing — square-footage rules of thumb are not.
AC installation: what to expect

M

MERV rating
Minimum Efficiency Reporting Value — a 1–16 scale of how well a filter captures particles. MERV 11–13 balances real filtration with airflow for most residential systems.
Air purifier vs. filter vs. UV

R

Refrigerant
The working fluid that carries heat through an AC or heat pump. It circulates in a sealed loop and is not consumed — 'needing a top-off' means there's a leak to find and fix.
RTU (Rooftop Unit)
A packaged commercial unit — heating, cooling, and blower in one cabinet on the roof. The standard equipment for storefronts, offices, and light commercial buildings.
Light commercial HVAC

S

SEER2 (Seasonal Energy Efficiency Ratio 2)
The current federal test standard for AC and heat pump cooling efficiency (successor to SEER, with more realistic test conditions). Higher numbers mean less electricity per unit of cooling.
Short cycling
Equipment starting and stopping in rapid cycles instead of running steadily. Causes include oversizing, dirty filters or coils, and failing controls — it raises bills and wears parts fast.
How central AC works
Single-stage / two-stage / modulating
How finely equipment can adjust output: single-stage is all-or-nothing; two-stage adds a low setting; modulating adjusts continuously. Higher staging runs longer and gentler — steadier temperatures and better dehumidification.
Static pressure
The resistance your duct system presents to airflow — HVAC's blood pressure. High static (undersized returns, restrictive filters) strains blowers and starves rooms.
Superheat / subcooling
The refrigerant measurements technicians use to verify correct charge. If a charge was set without measuring these, it was guessed.
What a tune-up should include

T

T&P valve (temperature & pressure relief)
The safety valve on a water heater that releases dangerous over-pressure. It should be tested during maintenance and never capped or plugged.
How long do water heaters last?

Z

Zoning
Dividing one duct system into independently controlled areas with motorized dampers and multiple thermostats — or achieving the same result with ductless heads per room.
HVAC zoning guide